典型文献
Ultrasensitive detection of IgE levels based on magnetic nanocapturer linked immunosensor assay for early diagnosis of cancer
文献摘要:
Rapid and accurate detection of immunoglobulin E(IgE)in serum and reduction of serum dosage are of great significance for clinical detection.Herein,we described a rapid magnetic separation of IgE from pa-tient serum based on Fe304@SiO2-NTA@026 sdab as the capture probe and multiple horseradish peroxi-dase(HRP)-labeled antibodies linked gold nanoparticles(AuNPs)as chemiluminescence(CL)signal ampli-fier for ultrasensitive detection of total IgE.Results showed that the limit of detection of our immunosen-sor system in serum samples was 0.03 kU/L,which is lowest in comparison with current methods,and far lower than that of ImmunoCAP for IgE detection(0.1 kU/L).Furthermore,our immunosensor pos-sessed satisfied repeatability and accuracy,as well as good stability.In comparison with the ImmunoCAP for the quantitative detection of IgE,highly consistent results were achieved in 20 serum samples.Spe-cially,this method was also successfully utilized for assessing the IgE traces in breast cancer patients,which provides a new idea for the diagnosis of early cancer.Therefore,we believe that such versatile immunosensor will offer an alternative method for the on-site monitoring and determination of various IgE-related diseases.
文献关键词:
中图分类号:
作者姓名:
Yongxin Liu;Mengda Cao;Zhongxi Huang;Changmin Yu;Naidi Yang;Qiong Wu;Liang Shi;Wenjie Duan;Yi Zhu;Jifu Wei;Lin Li;Wei Huang
作者机构:
Key Laboratory of Flexible Electronics(KLOFE)&Institute of Advanced Materials(IAM),Nanjing Tech University(NanjingTech),Nanjing 211816,China;Department of Pharmacy,Jiangsu Institute of Cancer Research&the Affiliated Cancer Hospital of Nanjing Medical University,Nanjing 210009,China;Department of Pharmacy,Zhongda Hospital,School of Medicine,Southeast University,Nanjing 210044,China;Research Division of Clinical Pharmacology&Clinical Allergy Center,the First Affiliated Hospital of Nanjing Medical University;Shaanxi Institute of Flexible Electronics(SIFE),Northwestern Polytechnical University(NPU),Xi'an 710072,China;State Key Laboratory of Coordination Chemistry,Nanjing University,Nanjing 210023,China
文献出处:
引用格式:
[1]Yongxin Liu;Mengda Cao;Zhongxi Huang;Changmin Yu;Naidi Yang;Qiong Wu;Liang Shi;Wenjie Duan;Yi Zhu;Jifu Wei;Lin Li;Wei Huang-.Ultrasensitive detection of IgE levels based on magnetic nanocapturer linked immunosensor assay for early diagnosis of cancer)[J].中国化学快报(英文版),2022(04):1855-1860
A类:
nanocapturer,sdab,immunosen
B类:
Ultrasensitive,detection,IgE,levels,magnetic,linked,immunosensor,assay,early,diagnosis,cancer,Rapid,accurate,immunoglobulin,serum,reduction,dosage,are,great,significance,clinical,Herein,described,rapid,separation,from,Fe304,SiO2,NTA,probe,multiple,horseradish,peroxi,dase,HRP,labeled,antibodies,gold,nanoparticles,AuNPs,chemiluminescence,CL,signal,ampli,fier,ultrasensitive,total,Results,showed,that,limit,our,system,samples,was,kU,which,lowest,comparison,current,methods,far,lower,than,ImmunoCAP,Furthermore,pos,sessed,satisfied,repeatability,accuracy,well,good,stability,In,quantitative,highly,consistent,results,were,achieved,Spe,cially,this,also,successfully,utilized,assessing,traces,breast,patients,provides,new,idea,Therefore,believe,such,versatile,will,offer,alternative,site,monitoring,determination,various,related,diseases
AB值:
0.608255
相似文献