Value of contrast-enhanced ultrasound combined with percutaneous ultrasound-guided fine-needle aspiration in the diagnosis of solid pancreatic lesions
文献摘要:
Background::Contrast-enhanced ultrasound (CEUS) can detect lesions hidden in inflammatory regions and find necrosis or areas of severe fibrosis within the lesion. This retrospective study aimed to compare the diagnostic accuracy of solid pancreatic lesions using percutaneous ultrasound (US)-guided fine-needle aspiration (FNA) with or without CEUS assessment.Methods::Clinical, imaging, and pathologic data of 181 patients from January 2014 to December 2018 in Pecking Union Medical College Hospital, with solid pancreatic masses who underwent percutaneous US-FNA and ThinPrep cytologic test were retrospectively evaluated. Patients were divided into CEUS and US groups according to whether CEUS was performed before the biopsy. According to FNA cytology diagnoses, we combined non-diagnostic, neoplastic, and negative cases into a negative category. The positive category included malignant, suspicious, and atypical cases. The final diagnosis was confirmed by pathology or clinical and radiological follow-up for at least 12 months. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of US-FNA were evaluated between the two groups.Results::This study enrolled 107 male and 74 female patients (average age: 60 years). There were 58 cases in the US group and 123 cases in the CEUS group. No statistically significant differences in age, gender, or lesion size were found between the two groups. The diagnostic accuracy of the CEUS group was 95.1% (117/123), which was higher than the 86.2% (50/58) observed in the US group (
P = 0.036). The sensitivity, specificity, PPV, and NPV of the CEUS group were increased by 7.5%, 16.7%, 3.4%, and 18.8%, respectively, compared with the US group. However, the differences of the two groups were not statistically significant.
Conclusions::Compared with the conventional US, the use of CEUS could improve the biopsy accuracy and avoid the need for a repeat biopsy, especially for some complicated FNA cases.
文献关键词:
Biopsy;Contrast-enhanced ultrasound;Cytology;Fine-needle aspiration;Pancreatic lesion;Pancreatic neoplasms;Percutaneous ultrasound
中图分类号:
作者姓名:
Gui Yang;Dai Menghua;Meng Zhilan;Chang Xiaoyan;Tan Li;Zhang Jing;Chen Xueqi;Zhou Tongtong;Zhang Qing;Xiao Mengsu;Lyu Ke;Jiang Yuxin
作者机构:
Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Pecking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Dongcheng District, Beijing 100730, China;Department of Surgery, State Key Laboratory of Complex Severe and Rare Diseases, Pecking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Dongcheng District, Beijing 100730, China;Department of Pathology, State Key Laboratory of Complex Severe and Rare Diseases, Pecking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Dongcheng District, Beijing 100730, China
文献出处:
引用格式:
[1]Gui Yang;Dai Menghua;Meng Zhilan;Chang Xiaoyan;Tan Li;Zhang Jing;Chen Xueqi;Zhou Tongtong;Zhang Qing;Xiao Mengsu;Lyu Ke;Jiang Yuxin-.Value of contrast-enhanced ultrasound combined with percutaneous ultrasound-guided fine-needle aspiration in the diagnosis of solid pancreatic lesions)[J].中华医学杂志(英文版),2022(04):426-432
A类:
Pecking,Cytology
B类:
Value,contrast,enhanced,ultrasound,combined,percutaneous,guided,fine,needle,aspiration,diagnosis,solid,pancreatic,lesions,Background,Contrast,CEUS,detect,hidden,inflammatory,regions,find,necrosis,areas,severe,fibrosis,within,This,study,aimed,diagnostic,accuracy,using,FNA,without,assessment,Methods,Clinical,imaging,pathologic,data,patients,from,January,December,Union,Medical,College,Hospital,masses,who,underwent,ThinPrep,cytologic,test,were,retrospectively,evaluated,Patients,divided,into,groups,according,whether,was,performed,before,biopsy,According,cytology,diagnoses,neoplastic,negative,cases,category,positive,included,malignant,suspicious,atypical,final,confirmed,by,pathology,clinical,radiological,follow,least,months,sensitivity,specificity,predictive,value,PPV,NPV,between,two,Results,enrolled,female,average,years,There,No,statistically,significant,differences,gender,size,found,which,higher,than,observed,increased,respectively,compared,However,not,Conclusions,Compared,conventional,use,could,improve,avoid,repeat,especially,some,complicated,Biopsy,Fine,Pancreatic,neoplasms,Percutaneous