典型文献
Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches
文献摘要:
The solid-phase microextraction technique quantifies analytes without considerably affecting the sample composition.Herein,a proof-of-concept study was conducted to demonstrate the use of coated probe electrospray ionization(coated-PESI)and coated blade spray(CBS)as ambient mass spectrometry ap-proaches for monitoring drug biotransformation.The ability of these methods was investigated for monitoring the dephosphorylation of a prodrug,combretastatin A4 phosphate(CA4P),into its active form,combretastatin A4(CA4),in a cell culture medium supplemented with fetal bovine serum.The CBS spot analysis was modified to achieve the same extraction efficiency as protein precipitation and ob-tained results in 7 min.Because coated-PESI performs extraction without consuming any samples,it is the preferred technique in the case of a limited sample volume.Although coated-PESI only extracts small quantities of analytes,it uses the desorption solvent volume of 5-10 pL,resulting in high sensitivity,thus allowing the detection of compounds after only 1 min of extraction.The biotransformation of CA4P into CA4 via phosphatases occurs within the simple matrix,and the proposed sample preparation techniques are suitable for monitoring the biotransformation.
文献关键词:
中图分类号:
作者姓名:
Karol Jaroch;Janusz Pawliszyn
作者机构:
Department of Chemistry,University of Waterloo,Waterloo,N2L 3G1,Canada;Department of Pharmacodynamics and Molecular Pharmacology,Faculty of Pharmacy,Collegium Medicum in Bydgoszcz,Nicolaus Copernicus University in Torun Poland,85090,Bydgoszcz,Poland
文献出处:
引用格式:
[1]Karol Jaroch;Janusz Pawliszyn-.Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches)[J].药物分析学报(英文),2022(01):186-191
A类:
B类:
Time,course,monitoring,vitro,biotransformation,reaction,via,solid,phase,microextraction,ambient,mass,spectrometry,approaches,quantifies,analytes,without,considerably,affecting,composition,Herein,proof,concept,study,was,conducted,demonstrate,coated,probe,electrospray,ionization,PESI,blade,CBS,ability,these,methods,investigated,dephosphorylation,prodrug,combretastatin,phosphate,CA4P,into,its,active,cell,culture,medium,supplemented,fetal,bovine,serum,spot,analysis,modified,achieve,same,efficiency,protein,precipitation,tained,results,Because,performs,consuming,any,samples,preferred,case,limited,volume,Although,only,extracts,small,quantities,uses,desorption,solvent,pL,resulting,high,sensitivity,thus,allowing,detection,compounds,after,phosphatases,occurs,within,simple,matrix,proposed,preparation,techniques,are,suitable
AB值:
0.574893
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。