首站-论文投稿智能助手
典型文献
Study on denoising of continuous spectrum on-line monitoring signal of water quality with micro-reagents based on HHT
文献摘要:
A continuous spectrum water quality on-line monitoring signal processing method based on Hilbert-Huang transform(HHT)is proposed in this paper,which combines the micro-reagent water quality on-line monitoring technology of sequential injection,The modulation signal and spectrum curve of each intrinsic mode function(IMF)component of the original spectrum signal were obtained by empirical mode decomposition(EMD).The water sample data of dif-ferent concentrations in the continuous spectrum on-line monitoring system was analyzed by the HHT model.The noise signal was excavated to realize the noise reduction processing,and the reconstruction of the continuous spectrum signal was realized after the noise reduction processing was completed.The research results show that this method can effectively reduce the noise of continuous spectrum signals according to different signal-to-noise characteristics of continuous spectrum,and has convenient use,fast processing speed,and high resolution in the time-frequency domain,which effectively improves the stability and accuracy of the micro-reagent continuous spectrum water quality on-line monitoring system,
文献关键词:
作者姓名:
LI Wen;Lü Binbin;FU Hao;CAI Yongqlng
作者机构:
Institute of Mechanical and Electrical Engineering,North China University of Technology,Beijing 100144,China
引用格式:
[1]LI Wen;Lü Binbin;FU Hao;CAI Yongqlng-.Study on denoising of continuous spectrum on-line monitoring signal of water quality with micro-reagents based on HHT)[J].光电子快报(英文版),2022(02):115-121
A类:
B类:
Study,denoising,continuous,spectrum,line,monitoring,water,quality,micro,reagents,HHT,processing,method,Hilbert,Huang,transform,proposed,this,paper,which,combines,technology,sequential,injection,modulation,curve,each,intrinsic,function,IMF,component,original,were,obtained,by,empirical,decomposition,EMD,sample,data,concentrations,system,was,analyzed,model,noise,excavated,reduction,reconstruction,realized,after,completed,research,results,show,that,can,effectively,reduce,signals,according,different,characteristics,has,convenient,use,fast,speed,high,resolution,frequency,domain,improves,stability,accuracy
AB值:
0.460405
相似文献
Quantitative analysis and time-resolved characterization of simulated tokamak exhaust gas by laser-induced breakdown spectroscopy
Yaxiong HE;Tao XU;Yong ZHANG;Chuan KE;Yong ZHAO;Shu LIU-School of Physics and Energy,Fujian Normal University,Fuzhou 350117,People's Republic of China;Center for Superconducting and New Energy Research and Development,Southwest Jiaotong University,Chengdu 610031,People's Republic of China;Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering,Fuzhou 350117,People's Republic of China;Shandong Dong Yi Optoelectronic Instrument Co.,Ltd,Yantai 264670,People's Republic of China;Technical Center for Industrial Product and Raw Material Inspection and Testing,Shanghai Customs,Shanghai 200135,People's Republic of China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。