Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST
文献摘要:
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The mea-surement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctua-tions in neutron emission induced by plasma magnetohy-drodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was con-ducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instru-ment express(PXIe)platform.The digital dual measure-ment modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing high-speed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 106 counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively.
文献关键词:
作者姓名:
Li Yang;Hong-Rui Cao;Jin-Long Zhao;Zi-Han Zhang;Qiang Li;Guo-Bin Wu;Yong-Qiang Zhang;Guo-Qiang Zhong;Li-Qun Hu;Zi-Jun Zhang
作者机构:
Institute of Plasma Physics,Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031,China;University of Science and Technology of China,Hefei 230026,China;Hefei University of Technology,Hefei 230009,China
引用格式:
[1]Li Yang;Hong-Rui Cao;Jin-Long Zhao;Zi-Han Zhang;Qiang Li;Guo-Bin Wu;Yong-Qiang Zhang;Guo-Qiang Zhong;Li-Qun Hu;Zi-Jun Zhang-.Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST)[J].核技术(英文版),2022(03):126-136
A类:
digitizing,fluctua,magnetohy,Campbelling
B类:
Development,wide,range,fast,response,pulse,signal,acquisition,system,neutron,flux,monitoring,EAST,fluctuation,reaches,six,orders,magnitude,between,ohmic,plasma,scenario,high,power,auxiliary,heating,advanced,superconducting,tokamak,NFM,significant,feedback,parameter,related,radiation,protection,information,rapid,tions,emission,induced,by,drodynamic,activity,Therefore,resolution,required,To,satisfy,these,requirements,digital,was,developed,present,study,using,field,programmable,gate,array,FPGA,peripheral,component,interconnect,extension,instru,express,PXIe,platform,dual,modes,which,composed,counting,AC,coupled,square,integral,were,designed,measurement,improved,from,ms,owing,utilizing,speed,analog,converters,ADCs,communication,direct,memory,access,DMA,online,data,preprocessing,technology,tested,experimentally,results,showed,that,counts,expanded,more,than,second,calibrated,multipoint,average,linear,fitting,method,subsequently,coefficient,reached,newly,ensures,meets,experiments,conducted,effectively
AB值:
0.469249
相似文献
Quantitative analysis and time-resolved characterization of simulated tokamak exhaust gas by laser-induced breakdown spectroscopy
Yaxiong HE;Tao XU;Yong ZHANG;Chuan KE;Yong ZHAO;Shu LIU-School of Physics and Energy,Fujian Normal University,Fuzhou 350117,People's Republic of China;Center for Superconducting and New Energy Research and Development,Southwest Jiaotong University,Chengdu 610031,People's Republic of China;Fujian Provincial Collaborative Innovation Center for Advanced High-Field Superconducting Materials and Engineering,Fuzhou 350117,People's Republic of China;Shandong Dong Yi Optoelectronic Instrument Co.,Ltd,Yantai 264670,People's Republic of China;Technical Center for Industrial Product and Raw Material Inspection and Testing,Shanghai Customs,Shanghai 200135,People's Republic of China
Space-resolved vacuum-ultraviolet spectroscopy for measuring impurity emission from divertor region of EAST tokamak
Liang HE;Yongcai SHEN;Hongming ZHANG;Bo LYU;Cheonho BAE;Huajiatnw JI;Chaoyang LI;Jia FU;Xuewei DU;Fudi WANG;Qiuping WANG;Xianghui YIN;Shunkuan WAN;Bin BIN;Yichao LI;Shuyu DAI-Institute of Plasma Physics,HFIPS,Chinese Academy of Sciences,Hefei 230031,People's Republic of China;University of Science and Technology of China,Hefei 230026,People's Republic of China;School of Physics and Materials Engineering,Hefei Normal University,Hefei 230601,People's Republic of China;Institute of Energy,Comprehensive National Science Center,Hefei 230026,People's Republic of China;School of Electrical Engineering,University of South of China,Hengyang 420001,People's Republic of China;Anhui Spectreation Instrument Co.Ltd,Hefei 230088,People's Republic of China;National Synchrotron Radiation Laboratory,University of Science and Technology of China,Hefei 230029,People's Republic of China;School of Physics,Dalian University of Technology,Dalian 116024,People's Republic of China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。