典型文献
Interobserver Agreement and Reliability of Intrapartum Nonreassuring Cardiotocography and Prediction of Neonatal Acidemia
文献摘要:
Objective::To evaluate the agreement and reliability of intrapartum nonreasurring cardiotocography (CTG) interpretation and prediction of neonatal acidemia by obstetricians working in different centers.Methods::A retrospective cohort study involving two tertiary hospitals (The First Affiliated Hospital of Sun Yat-sen University and Perking University Third Hospital) was conducted between 30
th September 2018 and 1
st April 2019. Six obstetricians from two hospitals with three levels of experience (junior, medium, and senior) reviewed 100 nonreassuring fetal heart rate (FHR) tracings from 1 hour before the onset of abnormalities until delivery. Each reviewer determined the FHR pattern, the baseline, variability, and presence of acceleration, deceleration, sinusoidal pattern, and predicted whether neonatal acidemia and abnormal umbilical arterial pH < 7.1 would occur. Inter-observer agreement was assessed using the proportions of agreement (Pa) and the proportion of specific agreement (Pa for each category). Reliability was evaluated with the kappa statistic (k-Light’s kappa for n raters) and Gwet’s AC1 statistic.
Results::Good inter-observer agreement was found in evaluation of most variables (Pa>0.5), with the exception of early deceleration (Pa= 0.39, 95% confidence interval (
CI): 0.36,0.43). Reliability was also good among most variables (AC1 > 0.40), except for acceleration, early deceleration, and prediction of neonatal acidemia (AC1 = 0.17, 0.10, and 0.25, respectively). There were no statistically significant differences among the three groups, except in the identification of accelerations (Pa = 0.89, 95%
CI: 0.83,0.95; Pa= 0.50, 95%
CI: 0.41,0.60, and Pa= 0.35, 95%
CI: 0.25,0.43 in junior, medium and senior groups, respectively) and the prediction of neonatal acidemia (Pa= 0.52, 0.52, and 0.62 in junior, medium and senior groups, respectively), where agreement was highest and lowest in the junior-level group, respectively. The accuracy and sensitivity of the prediction for umbilical artery pH < 7.1 were similar among the three groups, but the specificity was higher in the senior groups (93.68%
vs. 92.53%
vs. 98.85% in junior, medium and senior groups,
P= 0.015).
Conclusion::Although we found a good inter-observer agreement in the evaluation of the most basic CTG features and FHR category statistically, it was insufficient to meet the clinical requirements for "no objection" interpretation for FHR tracings. Further specialized training is needed for standardized interpretation of intrapartum FHR tracings.
文献关键词:
Cardiotocography;Fetal monitoring;Fetal distress
中图分类号:
作者姓名:
Li Zhuyu;Wang Yan;Cai Jian;Zhao Peizhen;Chen Hanqing;Liu Haiyan;Shen Lixia;Chen Lian;Li Shufang;Zhao Yangyu;Wang Zilian
作者机构:
Department of Obstetrics and Gynaecology, The First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, China;Department of Obstetrics and Gynaecology, Peking University Third Hospital, Beijing 100191, China;Dermatology Hospital, Southern Medical University, Guangzhou 510091, China
文献出处:
引用格式:
[1]Li Zhuyu;Wang Yan;Cai Jian;Zhao Peizhen;Chen Hanqing;Liu Haiyan;Shen Lixia;Chen Lian;Li Shufang;Zhao Yangyu;Wang Zilian-.Interobserver Agreement and Reliability of Intrapartum Nonreassuring Cardiotocography and Prediction of Neonatal Acidemia)[J].母胎医学杂志(英文),2022(02):95-102
A类:
Interobserver,Intrapartum,Nonreassuring,Cardiotocography,Acidemia,nonreasurring,cardiotocography,Perking,nonreassuring,tracings,reviewer,raters,Gwet,objection
B类:
Agreement,Reliability,Prediction,Neonatal,Objective,To,agreement,reliability,intrapartum,CTG,interpretation,prediction,neonatal,acidemia,by,obstetricians,working,different,centers,Methods,retrospective,cohort,study,involving,two,tertiary,hospitals,First,Affiliated,Hospital,Sun,Yat,University,Third,was,conducted,between,30
,September,1
,April,Six,from,three,levels,experience,junior,medium,senior,reviewed,fetal,heart,FHR,hour,before,onset,abnormalities,until,delivery,Each,determined,pattern,baseline,variability,presence,deceleration,sinusoidal,predicted,whether,umbilical,arterial,would,occur,assessed,using,proportions,Pa,each,category,evaluated,kappa,Light,AC1,Results,Good,found,evaluation,most,variables,exception,early,confidence,interval,also,good,among,respectively,There,were,statistically,significant,differences,groups,identification,accelerations,where,highest,lowest,accuracy,sensitivity,artery,similar,but,specificity,higher,Conclusion,Although,basic,features,insufficient,meet,clinical,requirements,Further,specialized,training,needed,standardized,Fetal,monitoring,distress
AB值:
0.414791
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。