首站-论文投稿智能助手
典型文献
B-scan-sectioned dynamic micro-optical coherence tomography for bulk-motion suppression
文献摘要:
In this Letter,we present B-scan-sectioned dynamic micro-optical coherence tomography[BD-MOCT]for high-quality sub-cellular dynamic contrast imaging.Dynamic micro-optical coherence tomography[D-MOCT]is a functional optical coher-ence tomography[OCT]technique performed on high-resolution[micron level]OCT systems;hundreds of consecutive B-scans need to be acquired for dynamic signal extraction,which requires relatively long data acquisition time.Bulk motions occurring during data acquisition[even at the micron level]may degrade the quality of the obtained dynamic contrast images.In BD-MOCT,each full B-scan is divided into several sub-B-scans,and each sub-B-scan repeats multiple times before the sample beam moves to the next sub-B-scan.After all of the sub-B-scans for a full B-scan are completely acquired,we stitch all of the sub-B-scans into the same number of full B-scans.In this way,the time interval between two consecutive stitched B-scans could be reduced multiple times for bulk-motion suppression.The performed scanning protocol modulates the scanning sequences of fast scanning and repeat scanning for improving the dynamic contrast image quality,while the total data acquisition time remains almost the same.
文献关键词:
作者姓名:
Chaoliang Chen;Weisong Shi;Zhiyuan Qiu;Victor X.D.Yang;Wanrong Gao
作者机构:
Advanced Photonics Center,School of Electronic Science & Engineering,Southeast University,Nanjing 210096,China;Department of Optical Engineering,Nanjing University of Science and Technology,Nanjing 210094,China;Department of Electrical,Computer,and Biomedical Engineering,Ryerson University,Toronto,Ontario M5B 2K3,Canada;Division of Neurosurgery,Sunnybrook Health Sciences Centre,Toronto,Ontario M4N 3M5,Canada;Division of Neurosurgery,Faculty of Medicine,University of Toronto,Toronto,Ontario M5T 1P5,Canada
引用格式:
[1]Chaoliang Chen;Weisong Shi;Zhiyuan Qiu;Victor X.D.Yang;Wanrong Gao-.B-scan-sectioned dynamic micro-optical coherence tomography for bulk-motion suppression)[J].中国光学快报(英文版),2022(02):34-39
A类:
MOCT
B类:
sectioned,dynamic,optical,coherence,tomography,bulk,suppression,In,this,Letter,present,BD,high,quality,sub,cellular,contrast,imaging,Dynamic,functional,technique,performed,resolution,micron,level,systems,hundreds,consecutive,scans,need,acquired,signal,extraction,which,requires,relatively,long,data,acquisition,Bulk,motions,occurring,during,even,may,degrade,obtained,images,each,full,divided,into,several,repeats,multiple,times,before,sample,beam,moves,next,After,all,are,completely,same,number,way,interval,between,two,stitched,could,reduced,scanning,protocol,modulates,sequences,fast,improving,while,total,remains,almost
AB值:
0.446654
相似文献
Dynamic nitrogen vacancy magnetometry by single-shot optical streaking microscopy
Mark A. Keppler;Zachary A. Steelman;Zachary N. Coker;Milo? Nesládek;Philip R. Hemmer;Vladislav V. Yakovlev;Joel N. Bixler-Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, USA;SAIC, JBSA Fort Sam Houston, Texas 78234, USA;National Research Council Research Associateship Program, Washington, DC 20001, USA;IMOMEC Division, IMEC, B-3590 Diepenbeek, Belgium;Institute for Materials Research (IMO), Hasselt University, B-3590 Diepenbeek, Belgium;Czech Technical University in Prague, 27201 Kladno, Czech Republic;Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77843, USA;Bioeffects Division, Airman System Directorate, Air Force Research Laboratory, JBSA Fort Sam Houston, Texas 78234, USA;e-mail: yakovlev@tamu.edu
Dynamic nitrogen vacancy magnetometry by single-shot optical streaking microscopy
MARK A.KEPPLER;ZACHARY A.STEELMAN;ZACHARY N.COKER;MILO? NESLáDEK;PHILIP R.HEMMER;VLADISLAV V.YAKOVLEV;JOEL N.BIXLER-Department of Biomedical Engineering,Texas A&M University,College Station,Texas 77843,USA;SAIC,JBSA Fort Sam Houston,Texas 78234,USA;National Research Council Research Associateship Program,Washington,DC 20001,USA;IMOMEC Division,IMEC,B-3590 Diepenbeek,Belgium;Institute for Materials Research(IMO),Hasselt University,B-3590 Diepenbeek,Belgium;Czech Technical University in Prague,27201 Kladno,Czech Republic;Department of Electrical and Computer Engineering,Texas A&M University,College Station,Texas 77843,USA;Bioeffects Division,Airman System Directorate,Air Force Research Laboratory,JBSA Fort Sam Houston,Texas 78234,USA
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。