首站-论文投稿智能助手
典型文献
Pencil-beam scanning catheter for intracoronary optical coherence tomography
文献摘要:
Current gradient-index (GRIN) lens based proximal-driven intracoronary optical coherence tomography (ICOCT) probes consist of a spacer and a GRIN lens with large gradient constant. This design provides great flexibility to control beam profiles, but the spacer length should be well controlled to obtain desired beam profiles and thus it sets an obstacle in mass catheter fabrication. Besides, although GRIN lens with large gradient constant can provide tight focus spot, it has short depth of focus and fast-expanded beam which leads to poor lateral resolution for deep tissue. In this paper, a type of spacer-removed probe is demonstrated with a small gradient constant GRIN lens. This design simplifies the fabrica-tion process and is suitable for mass production. The output beam of the catheter is a narrow nearly collimated light beam, referred to as pencil beam here. The full width at half maximum beam size varies from 35.1 μm to 75.3 μm in air over 3-mm range. Probe design principles are elaborated with probe/catheter fabrication and performance test. The in vivo imaging of the catheter was verified by a clinical ICOCT system. Those results prove that this novel pencil-beam scanning catheter is potentially a good choice for ICOCT systems.
文献关键词:
作者姓名:
Jiqiang Kang;Rui Zhu;Yunxu Sun;Jianan Li;Kenneth K.Y.Wong
作者机构:
School of Electronic and Information Engineering,Harbin Institute of Technology(Shenzhen),Shenzhen 518055,China;International Graduate School at Shenzhen,Tsinghua University,Shenzhen 518055,China;Shenzhen Vivolight Medical Device&Technology Co.,Ltd.,Shenzhen 518055,China;State Key Laboratory of Transient Optics and Photonics,Xi'an Institute of Optics and Precision Mechanics,Chinese Academy of Sciences,Xi'an 710119,China;Department of Electrical and Electronic Engineering,The University of Hong Kong,Pokfulam Road,Hong Kong,China;Advanced Biomedical Instrumentation Centre,Hong Kong Science Park,Shatin,New Territories,Hong Kong,China
引用格式:
[1]Jiqiang Kang;Rui Zhu;Yunxu Sun;Jianan Li;Kenneth K.Y.Wong-.Pencil-beam scanning catheter for intracoronary optical coherence tomography)[J].光电进展(英文版),2022(03):69-75
A类:
Pencil,intracoronary,ICOCT
B类:
beam,scanning,catheter,optical,coherence,tomography,Current,gradient,GRIN,lens,proximal,driven,probes,consist,spacer,large,constant,This,design,provides,great,flexibility,profiles,but,length,should,well,controlled,obtain,desired,thus,sets,obstacle,mass,fabrication,Besides,although,tight,focus,spot,has,short,depth,fast,expanded,which,leads,poor,lateral,resolution,deep,tissue,In,this,paper,type,removed,demonstrated,small,simplifies,process,suitable,production,output,narrow,nearly,collimated,light,referred,pencil,full,width,half,maximum,size,varies,from,air,over,range,Probe,principles,are,elaborated,performance,test,vivo,imaging,was,verified,by,clinical,Those,results,prove,that,novel,potentially,good,choice,systems
AB值:
0.523193
相似文献
Terahertz structured light:nonparaxial Airy imaging using silicon diffractive optics
Rusnè lva?kevi?iūtè-Povilauskienè;Paulius Kizevi?ius;Ernestas Nacius;Domas Jokubauskis;K?stutis lkamas;Alvydas Lisauskas;Natalia Alexeeva;leva Matulaitienè;Vytautas Jukna;Sergej Orlov;Linas Minkevi?ius;Gintaras Valu?is-Department of Optoelectronics,Center for Physical Sciences and Technology,Sauletekio av.3,Vilnius 10257,Lithuania;Department of Fundamental Research,Center for Physical Sciences and Technology,Saulètekio av.3,Vilnius 10257,Lithuania;Institute of Applied Electrodynamics&Telecommunications,Vilnius University,Saulètekio av.3,Vilnius 10257,Lithuania;CENTERA Labs.,Institute of High Pressure Physics PAS,ul.Sokolowska 29/37,Warsaw 01-142,Poland;Department of Organic Chemistry,Center for Physical Sciences and Technology,Saulètekio av.3,Vilnius 10257,Lithuania;Institute of Photonics and Nanotechnology,Department of Physics,Vilnius University,Saulètekio av.3,Vilnius 10257,Lithuania
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。