典型文献
Modifying current thin-film microextraction(TFME)solutions for analyzing prohibited substances:Evaluating new coatings using liquid chromatography
文献摘要:
For identifying and quantifying prohibited substances,solid-phase microextraction(SPME)continues to arouse interest as a sample preparation method.However,the practical implementation of this method in routine laboratory testing is currently hindered by the limited number of coatings compatible with the ubiquitous high-performance liquid chromatography(HPLC)systems.Only octadecyl(C18)and poly-dimethylsiloxane/divinylbenzene ligands are currently marketed for this purpose.To address this situ-ation,the present study evaluated 12 HPLC-compatible coatings,including several chemistries not currently used in this application.The stationary phases of SPME devices in the geometry of thin film-coated blades were prepared by applying silica particles bonded with various functional ligands(C18,octyl,phenyl-hexyl,3-cyanopropyl,benzenesulfonic acid,and selected combinations of these),as well as unbonded silica,to a metal support.Most of these chemistries have not been previously used as microextraction coatings.The 48 most commonly misused substances were selected to assess the extraction efficacy of each coating,and eight desorption solvent compositions were used to optimize the desorption conditions.All samples were analyzed using an HPLC system coupled with triple quadrupole tandem mass spectrometry.This evaluation enables selection of the best-performing coatings for quantifying prohibited substances and investigates the relationship between extraction efficacy and the physicochemical characteristics of the analytes.Ultimately,using the most suitable coatings is essential for trace-level analysis of chemically diverse prohibited substances.
文献关键词:
中图分类号:
作者姓名:
?ukasz Sobczak;Dominika Ko?odziej;Krzysztof Goryński
作者机构:
Bioanalysis Scientific Group,Faculty of Pharmacy,Collegium Medicum in Bydgoszcz at Nicolaus Copernicus University in Toruń,85-089,Bydgoszcz,Poland
文献出处:
引用格式:
[1]?ukasz Sobczak;Dominika Ko?odziej;Krzysztof Goryński-.Modifying current thin-film microextraction(TFME)solutions for analyzing prohibited substances:Evaluating new coatings using liquid chromatography)[J].药物分析学报(英文),2022(03):470-480
A类:
TFME,octadecyl,cyanopropyl,benzenesulfonic,misused
B类:
Modifying,thin,film,microextraction,solutions,analyzing,prohibited,substances,Evaluating,new,coatings,using,liquid,chromatography,For,identifying,quantifying,solid,SPME,continues,arouse,interest,preparation,method,However,practical,implementation,this,routine,laboratory,testing,currently,hindered,by,limited,number,compatible,ubiquitous,high,performance,HPLC,systems,Only,C18,poly,dimethylsiloxane,divinylbenzene,ligands,marketed,purpose,To,address,situ,present,study,evaluated,including,several,chemistries,not,application,stationary,phases,devices,geometry,coated,blades,were,prepared,applying,silica,particles,various,functional,octyl,phenyl,hexyl,acid,selected,combinations,these,well,unbonded,metal,support,Most,have,been,previously,most,commonly,assess,efficacy,each,eight,desorption,solvent,compositions,optimize,conditions,All,samples,analyzed,coupled,triple,quadrupole,tandem,mass,spectrometry,This,evaluation,enables,selection,best,performing,investigates,relationship,between,physicochemical,characteristics,analytes,Ultimately,suitable,essential,trace,level,analysis,chemically,diverse
AB值:
0.58571
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。