首站-论文投稿智能助手
典型文献
Design of Implant Prosthesis for Bone Injury Repair Considering Stress Shielding Effect
文献摘要:
The failure of bone injury repair surgery is mostly due to the stress shielding effect caused by the difference of elastic modulus between the implant prosthesis and human bone, result-ing in a great damage to patients. To solve this problem, in this study, the influencing factors of the elastic modulus of implant prosthesis were investigated, the relationship between the elastic modulus of the implanted prosthesis and the influencing factors was analyzed, and then a design method of the implant prosthesis to reduce the stress shielding effect by adjusting the unit module to control the elastic modulus was established. This method was used for the biomechanical simula-tion to simulate the displacement and stress distribution between the implant prosthesis and the surrounding bone tissue, and then the reliability of the method was verified. The implant prosthe-sis with an elastic modulus consistent with that of the experimental dog bone was made by this method, and used for the animal experiments. The effects of implant prosthesis with different mod-ulus on the growth of surrounding bone tissue were observed, and at the same time, the reliability of the implant design method and the results of biomechanical simulation were verified. It is con-firmed that this method can effectively reduce the stress concentration of implant prosthesis by more than 15.4% and increase the growth of bone tissue by more than 21%.
文献关键词:
作者姓名:
Yixin Shao;Ye Zhu;Tianmin Guan;Qi Hu;Baozhong Wei;Bing Lin;Liyan Zhang;Qian Cao
作者机构:
School of Mechanical Engineering, Dalian Jiaotong University, Dalian 116028, Liaoning, China;School of Mechanical Engineering, BeihuaUniversity, Jilin 132021, Jilin, China;Jilin City Orthopedic Hospital, Jilin132001, Jilin, China;First Department of GeneralSurgery, Affiliated Hospital of Beihua University, Jilin132013, Jilin, China;Dalian Stomatological Hospital, Dalian116021, Liaoning, China;First Department of Orthopedics,Affiliated Hospital of Beihua University, Jilin 132013, Jilin,China;Radiology Department, Second AffiliatedHospital of Dalian Medical University, Dalian 116023,Liaoning, China
引用格式:
[1]Yixin Shao;Ye Zhu;Tianmin Guan;Qi Hu;Baozhong Wei;Bing Lin;Liyan Zhang;Qian Cao-.Design of Implant Prosthesis for Bone Injury Repair Considering Stress Shielding Effect)[J].北京理工大学学报(英文版),2022(03):259-274
A类:
Prosthesis,prosthe
B类:
Design,Implant,Bone,Injury,Repair,Considering,Stress,Shielding,Effect,failure,bone,injury,repair,surgery,mostly,due,stress,shielding,caused,by,difference,elastic,modulus,between,prosthesis,human,great,damage,patients,To,solve,this,problem,study,influencing,factors,were,investigated,relationship,implanted,was,analyzed,then,design,method,reduce,adjusting,unit,module,control,established,This,biomechanical,simulate,displacement,distribution,surrounding,tissue,reliability,verified,consistent,that,experimental,dog,made,animal,experiments,effects,different,growth,observed,same,results,simulation,It,firmed,can,effectively,concentration,more,than,increase
AB值:
0.403903
相似文献
3D-Printed Scaffolds Promote Angiogenesis by Recruiting Antigen-Specific T Cells
Cuidi Li;Zhenjiang Ma;Wentao Li;Tianyang Jie;Liping Zhong;Hongfang Chen;Wenhao Wang;Jinwu Wang;Wenguo Cui;Yongxiang Zhao-Department of Orthopaedics,Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases,Shanghai Institute of Traumatology and Orthopaedics,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;Department of Orthopedic Surgery,Shanghai Key Laboratory of Orthopedic Implants,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200011,China;National Center for International Research of Bio-targeting Theranostics,Guangxi Key Laboratory of Bio-targeting Theranostics,Collaborative Innovation Center for Targeting Tumor Theranostics,Guangxi Medical University,Nanning 530021,China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。