首站-论文投稿智能助手
典型文献
Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
文献摘要:
The insertion torque of a dental implant is an important indicator for the primary stability of dental implants.Thus,the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.In this present research,an alternative method for prediction of implant torque was proposed.First,the mechanical model for the insertion torque was established based on an oblique cutting process.In the proposed mechanical model,three factors,including bone quality,implant geometry and surgical methods were considered in terms of bone-qual-ity coefficients,chip load and insertion speeds,respectively.Then,the defined bone-quality coeffiicients for cancellous bone with the computed tomography(CT)value of 235-245,345-355 and 415-425 Hu were obtained by a series of insertion experiments of IS and ITI implants.Finally,the insertion experiments of DIO implants were carried out to verify the accuracy of developed model.The predicted insertion torques calculated by the mechanical model were compared with those acquired by insertion experiments,with good agreement,the relative error being less than 15%.This method allows the insertion torque for different implant types to be quickly established and enhances prediction accuracy by considering the effects of implants'geometries and surgical methods.
文献关键词:
作者姓名:
Luli Li;Song Zhang;Quhao Li;Cuirong Bian;Airong Zhang
作者机构:
School of Mechanical Engineering,Shandong University,Jinan 250061,China;Key Laboratory of High-efficiency and Clean Mechanical Manufacture of Ministry of Education,Jinan,China;Department of Prosthodontics,Qilu Hospital of Shandong University,Jinan 250012,China
引用格式:
[1]Luli Li;Song Zhang;Quhao Li;Cuirong Bian;Airong Zhang-.Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant)[J].中国机械工程学报,2022(03):92-105
A类:
coeffiicients
B类:
Oblique,Cutting,Based,Mechanical,Model,Insertion,Torque,Dental,Implant,insertion,dental,important,indicator,primary,stability,implants,Thus,preoperative,prediction,crucial,improve,success,rate,implantation,surgery,this,present,research,alternative,was,proposed,First,mechanical,model,established,oblique,cutting,process,three,factors,including,bone,quality,geometry,surgical,methods,were,considered,terms,coefficients,chip,load,speeds,respectively,Then,defined,cancellous,computed,tomography,value,Hu,obtained,by,series,experiments,IS,ITI,Finally,DIO,carried,out,verify,accuracy,developed,predicted,torques,calculated,compared,those,acquired,good,agreement,relative,error,being,less,than,This,allows,different,types,quickly,enhances,considering,effects,geometries
AB值:
0.539535
相似文献
3D-Printed Scaffolds Promote Angiogenesis by Recruiting Antigen-Specific T Cells
Cuidi Li;Zhenjiang Ma;Wentao Li;Tianyang Jie;Liping Zhong;Hongfang Chen;Wenhao Wang;Jinwu Wang;Wenguo Cui;Yongxiang Zhao-Department of Orthopaedics,Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases,Shanghai Institute of Traumatology and Orthopaedics,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;Department of Orthopedic Surgery,Shanghai Key Laboratory of Orthopedic Implants,Shanghai Ninth People's Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200011,China;National Center for International Research of Bio-targeting Theranostics,Guangxi Key Laboratory of Bio-targeting Theranostics,Collaborative Innovation Center for Targeting Tumor Theranostics,Guangxi Medical University,Nanning 530021,China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。