典型文献
Layperson's performance on an unconversant type of AED device: A prospective crossover simulation experimental study
文献摘要:
BACKGROUND: Diverse models of automated external defibrillators (AEDs) possess distinctive features. This study aimed to investigate whether laypersons trained with one type of AED could intelligently use another initial contact type of AED with varying features. METHODS: This was a prospective crossover simulation experimental study conducted among college students. Subjects were randomly trained with either AED1 (AED1 group) or AED2 (AED2 group), and the AED operation performance was evaluated individually (Phase I test). At the 6-month follow-up AED performance test (Phase Ⅱ test), half of the subjects were randomly switched to use another type of AED, which formed two switches (Switch A: AED1-1 group vs. AED2-1 group; Switch B: AED2-2 group vs. AED1-2 group). RESULTS: A total of 224 college students participated in the study. In the phase I test, a significantly higher proportion of successful defibrillation and shorter shock delivery time to achieve successful defibrillation was observed in the AED2 group than in the AED1 group. In the phase Ⅱ test, no statistical differences were observed in the proportion of successful defibrillation in Switch A (51.4% vs. 36.6%, P=0.19) and Switch B (78.0% vs. 53.7%, P=0.08). The median shock delivery time within participants achieving successful defibrillation was significantly longer in the switched group than that of the initial group in both Switch A (89 [81–107] s vs. 124 [95–135] s, P=0.006) and Switch B (68 [61.5–81.5] s vs. 95.5 [55–131] s, P<0.001). CONCLUSION: College students were able to effectively use AEDs different from those used in the initial training after six months, although the time to shock delivery was prolonged.
文献关键词:
中图分类号:
作者姓名:
Chao-yu Lei;Heng-wei Qin;Xue-jie Dong;Jia-lin You;Lin Zhang
作者机构:
Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;Department of Global Health,School of Public Health,Peking University,Beijing 100191,China;School of Public Health,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;School of Nursing,Shanghai Jiao Tong University,Shanghai 200025,China
文献出处:
引用格式:
[1]Chao-yu Lei;Heng-wei Qin;Xue-jie Dong;Jia-lin You;Lin Zhang-.Layperson's performance on an unconversant type of AED device: A prospective crossover simulation experimental study)[J].世界急诊医学杂志(英文),2022(02):98-105
A类:
Layperson,unconversant,defibrillators,laypersons,AED1,AED2,defibrillation
B类:
performance,type,device,prospective,crossover,simulation,experimental,study,BACKGROUND,Diverse,models,automated,external,AEDs,possess,distinctive,features,This,aimed,investigate,whether,trained,one,could,intelligently,another,initial,contact,varying,METHODS,was,conducted,among,college,students,Subjects,were,randomly,either,group,operation,evaluated,individually,Phase,test,At,follow,half,subjects,switched,which,formed,two,switches,Switch,RESULTS,total,participated,In,phase,significantly,higher,proportion,successful,shorter,shock,delivery,achieve,observed,than,statistical,differences,median,within,participants,achieving,longer,that,both,CONCLUSION,College,able,effectively,different,from,those,used,training,after,six,months,although,prolonged
AB值:
0.41135
相似文献