首站-论文投稿智能助手
典型文献
Theoretical and experimental assessment of a novel method to establish the complete measurement range of the calorimeter and its limit of detection and quantification
文献摘要:
For determining the accuracy of a calorimeter over the instrument's entire measuring range,a novel method has been established.For this new approach,(a)benzoic acid(C6H5CO2H)as a certified reference material(CRM),(b)SiO2 and(c)a mixture of CRM benzoic acid and SiO2 have been used.To illustrate the essential difference between 1)the novel analytical method for control of the entire measurement range and 2)the calorimeter calibration,both applications of benzoic acid(BA)have been demonstrated.An experimental result showed that BA was successfully used to check the whole calorimeter measurement range.The results also showed that the same new method was successfully applied to determine the limit of detection and quantification.A new instrument testing process and a new measurement technique have thus been established.In this way,the cost of using CRM to control the accuracy of measuring the entire measuring range of the calorimeter,as shown in this paper,is minimized.The requirements of the ISO/IEC 17025:2017 standard are satisfied.ISO/IEC 17025:2017,together with ISO 9001:2015(quality management systems),ISO 14001:2015(relate to environmental protection)and ISO 45001:2018(occupational safety),constitute an integrated quality system by which a testing laboratory may also accredit.
文献关键词:
作者姓名:
Vesna Krsti?
作者机构:
Mining and Metallurgy Institute Bor,Zeleni Bulevar 35,19210 Bor,Serbia;University of Belgrade,Technical Faculty Bor,VJ 12,19210 Bor,Serbia
引用格式:
[1]Vesna Krsti?-.Theoretical and experimental assessment of a novel method to establish the complete measurement range of the calorimeter and its limit of detection and quantification)[J].中国化学工程学报(英文版),2022(04):466-473
A类:
C6H5CO2H,accredit
B类:
Theoretical,experimental,assessment,novel,method,complete,measurement,range,calorimeter,its,limit,detection,quantification,For,determining,accuracy,over,instrument,entire,measuring,has,been,established,this,new,approach,benzoic,acid,certified,reference,material,CRM,SiO2,mixture,have,used,To,illustrate,essential,difference,between,analytical,control,calibration,both,applications,BA,demonstrated,An,showed,that,was,successfully,check,whole,results,also,same,applied,determine,testing,process,technique,thus,In,way,cost,using,shown,paper,minimized,requirements,ISO,IEC,standard,are,satisfied,together,quality,management,systems,relate,environmental,protection,occupational,safety,constitute,integrated,by,which,laboratory,may
AB值:
0.499332
相似文献
A simple,rapid,and practical method for single-cell proteomics based on mass-adaptive coating of synthetic peptides
Siqi Li;Kaichan Su;Zhenkun Zhuang;Qing Qin;Lei Gao;Yamei Deng;Xuyang Liu;Guixue Hou;Longtao Wang;Piliang Hao;Huanming Yang;Siqi Liu;Hongming Zhu;Yan Ren-BGI-Shenzhen,Shenzhen 518083,China;Department of Biology,University of Copenhagen,Copenhagen 2100,Denmark;BGI-Wuhan Clinical Laboratories,BGI-Shenzhen,Wuhan 430000,China;Department of Cardiology,Zhongshan Hospital,Fudan University,Shanghai Institute of Cardiovascular Disease,Shanghai 200032,China;Department of Cardiovascular Surgery,The First Affiliated Hospital of USTC,Division of Life Sciences and Medicine,University of Science and Technology of China(USTC),Hefei 230001,China;School of Life Science and Technology,Shanghai Tech University,Shanghai 201210,China;Institute for Regenerative Medicine,Shanghai East Hospital,Tongji University School of Medicine,Shanghai 200120,China;Experiment Center for Science and Technology,Shanghai University of Traditional Chinese Medicine,Shanghai 201203,China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。