Design of a real-time fiber-optic infrared imaging system with wide-angle and large depth of field
文献摘要:
A key limitation in the observation of instruments used in operations and heart sutures during a procedure is the scattering and absorption during optical imaging in the presence of blood.Therefore,we propose a novel real-time fiber-optic infrared imaging system simultaneously capturing a flexible wide field of view[FOV]and large depth of field infrared image in real time.The assessment criteria for imaging quality of the objective and coupling lens have been optimized and evaluated.Furthermore,the feasibility of manufacturing and assembly has been demonstrated with tolerance sensitivity and the Monte Carlo analysis.The simulated results show that the optical system can achieve a large working distance of 8 to 25 mm,a wide FOV of 120°,and the relative illuminance is over 0.98 in the overall FOV.To achieve high imaging quality in the proposed system,the modulation transfer function is over 0.661 at 16.7 Ip/mm for a 320 × 256 short wavelength infrared camera sensor with a pixel size of 30 μm.
文献关键词:
作者姓名:
Xing Peng;Lingbao Kong
作者机构:
Shanghai Engineering Research Center of Ultra-precision Optical Manufacturing,School of Information Science and Technology,Fudan University,Shanghai 200433,China
引用格式:
[1]Xing Peng;Lingbao Kong-.Design of a real-time fiber-optic infrared imaging system with wide-angle and large depth of field)[J].中国光学快报(英文版),2022(01):29-36
A类:
B类:
Design,real,fiber,infrared,imaging,system,wide,angle,large,depth,field,key,limitation,observation,instruments,used,operations,heart,sutures,during,procedure,scattering,absorption,optical,presence,blood,Therefore,we,novel,simultaneously,capturing,flexible,view,FOV,image,assessment,criteria,quality,objective,coupling,lens,have,been,optimized,evaluated,Furthermore,feasibility,manufacturing,assembly,has,demonstrated,tolerance,sensitivity,Monte,Carlo,analysis,simulated,results,show,that,can,achieve,working,distance,relative,illuminance,overall,To,high,proposed,modulation,transfer,function,Ip,short,wavelength,camera,sensor,pixel,size
AB值:
0.591623
相似文献
Mid-infrared active metasurface based on Si/VO2 hybrid meta-atoms
TONGTONG KANG;BOYU FAN;JUN QIN;WEIHAO YANG;SHUANG XIA;ZHENG PENG;BO LIU;SUI PENG;XIAO LIANG;TINGTING TANG;LONGJIANG DENG;YI LUO;HANBIN WANG;QIANG ZHOU;LEI BI-National Engineering Research Center of Electromagnetic Radiation Control Materials,University of Electronic Science and Technology of China,Chengdu 610054,China;State Key Laboratory of Electronic Thin-Films and Integrated Devices,University of Electronic Science and Technology of China,Chengdu 610054,China;Institute of Fundamental and Frontier Sciences,University of Electronic Science and Technology of China,Chengdu 610054,China;College of Optoelectronic Engineering,Chengdu University of Information Technology,Chengdu 610225,China;State Key Laboratory of Vanadium and Titanium Resources Comprehensive Utilization,Panzhihua 617000,China;Microsystem&Terahertz Research Center,China Academy of Engineering Physics(CAEP),Chengdu 610200,China;Institute of Electronic Engineering,China Academy of Engineering Physics(CAEP),Mianyang 621900,China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。