A beam range monitor based on scintillator and multi-pixel photon counter arrays for heavy ions therapy
文献摘要:
Fast beam range measurements are required to maximize the time available for patient treatment,given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning standards and ensure patient safety.A novel beam range monitor based on a plastic scintillator and multi-pixel photon counter(MPPC)arrays is therefore proposed in this paper.The monitor was constructed using 128 plastic scintillator films with a thickness of 1 mm and an active area of 50×50 mm2.A customized MPPC array read the scintillation light of each film.The advantage of dividing the active detector volume into films is that it intercepts the particle beam and enables direct differential light yield measurement in each film,in addition to depth-light curve generation without the need for image analysis.A GEANT4 simulation,including scintillator quenching effects,was implemented,and the results revealed that Birks'law exhibited a slight little influence on the position of the beam range,only changing the shape and absolute normalization of the Bragg curve,which is appropriate for the calculation of the beam range using the depth-light curve.The performance of the monitor was evaluated using a heavy-ion medical machine in Wuwei City,Gansu Pro-vince,China.The beam range measurement accuracy of the monitor was 1 mm,and the maximum difference between the measured and reference ranges was less than 0.2%,thus indicating that the monitor can meet clinical carbon ion therapy requirements.
文献关键词:
中图分类号:
作者姓名:
Wei Wang;Xiao-Xiao Yuan;Xiao-Hong Cai
作者机构:
Institute of Modern Physics,Chinese Academy of Sciences,Lanzhou 730000,China;University of Chinese Academy of Sciences,Beijing 100049,China
文献出处:
引用格式:
[1]Wei Wang;Xiao-Xiao Yuan;Xiao-Hong Cai-.A beam range monitor based on scintillator and multi-pixel photon counter arrays for heavy ions therapy)[J].核技术(英文版),2022(10):11-21
A类:
Birks,vince
B类:
beam,monitor,scintillator,multi,pixel,photon,counter,arrays,heavy,ions,therapy,Fast,measurements,required,maximize,available,patient,treatment,given,that,requires,verification,respect,quality,assurance,maintain,accelerator,commissioning,standards,ensure,safety,novel,plastic,MPPC,therefore,proposed,this,paper,was,constructed,using,films,thickness,active,area,mm2,customized,read,scintillation,each,advantage,dividing,detector,volume,into,intercepts,particle,enables,direct,differential,yield,addition,depth,curve,generation,without,need,image,analysis,GEANT4,simulation,including,quenching,effects,implemented,results,revealed,law,exhibited,slight,little,influence,position,only,changing,shape,absolute,normalization,Bragg,which,appropriate,calculation,performance,evaluated,medical,machine,Wuwei,City,Gansu,Pro,China,accuracy,maximum,difference,between,measured,reference,ranges,less,than,thus,indicating,can,meet,clinical,carbon,requirements
AB值:
0.554974
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。