Residual field suppression for magnetocardiography measurement inside a thin magnetically shielded room using bi-planar coil
文献摘要:
For a magnetocardiography(MCG)system inside a magnetically shielded room(MSR),the residual field should be further suppressed to obtain high-quality MCG signals.In this paper,a compensation system has been developed based on the bi-planar coil and the proportional-integral-derivative(PID)controller.The bi-planar coil,derived from the target-field theory and the Tikhonov regularization method,is utilized to generate magnetic field with high uniformity in the pre-defined target region.And the PID controller is introduced to provide dynamic compensation current for the coil,according to the residual field change monitored by a reference SQUID magnetometer.The measurement results show that the noise suppression ratio(NSR)can reach above 20 dB in the low-frequency range from 0.1 Hz to 50 Hz.The DC component and the fluctuation of the residual field in time-domain can be respectively suppressed to 0 pT and 4 pT,indicating that this proposed compensation method is useful for the MCG measurement.
文献关键词:
作者姓名:
Kang Yang;Hong-Wei Zhang;Qian-Nian Zhang;Jun-Jun Zha;Deng-Chao Huang
作者机构:
College of Electrical Engineering,Anhui Polytechnic University,Wuhu 241000,China;Key Laboratory of Advanced Perception and Intelligent Control of High-end Equipment,Ministry of Education,Anhui Polytechnic University,Wuhu 241000,China
引用格式:
[1]Kang Yang;Hong-Wei Zhang;Qian-Nian Zhang;Jun-Jun Zha;Deng-Chao Huang-.Residual field suppression for magnetocardiography measurement inside a thin magnetically shielded room using bi-planar coil)[J].中国物理B(英文版),2022(07):258-263
A类:
magnetocardiography
B类:
Residual,field,suppression,measurement,inside,thin,magnetically,shielded,room,using,bi,planar,coil,For,MCG,system,MSR,residual,should,further,suppressed,obtain,high,quality,signals,In,this,paper,compensation,has,been,developed,proportional,integral,derivative,PID,controller,derived,from,target,theory,Tikhonov,regularization,method,utilized,generate,uniformity,defined,region,And,introduced,provide,dynamic,current,according,change,monitored,by,reference,SQUID,magnetometer,results,show,that,noise,ratio,NSR,can,reach,above,dB,low,frequency,range,DC,component,fluctuation,domain,respectively,pT,indicating,proposed,useful
AB值:
0.543141
相似文献
Physical design of a new set of high poloidal mode number coils in the EAST tokamak
Liang LIAO;Yunfeng LIANG;Shaocheng LIU;Huaxiang ZHANG;Xiang JI;Youwen SUN;Wenyin WEI;Huihui WANG;Jinping QIAN;Liang WANG;Manni JIA;Long ZENG;Xiang GAO;EAST Team-Institute of Plasma Physics,Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031,People's Republic of China;University of Science and Technology of China,Hefei 230026,People's Republic of China;Forschungszentrum Jüilich GmbH,Institut für Energie-und Klimaforschung—Plasmaphysik,Partner of the Trilateral Euregio Cluster(TEC),Jülich D-52425,Germany;International Joint Research Laboratory of Magnetic Confinement Fusion and Plasma Physics,State Key Laboratory of Advanced Electromagnetic Engineering and Technology,School of Electrical and Electronic Engineering,Huazhong University of Science and Technology,Wuhan 430074,People's Republic of China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。