典型文献
Clinical outcomes with a new design in multifocal intraocular lens:a pilot study
文献摘要:
Purpose:To evaluate the clinical and visual outcomes,quality of near vision and the influence of photic phenomena in patients bilaterally implanted with a new Precizon Presbyopic multifocal intraocular lens(IOL).Methods:In this prospective consecutive case series,20 eyes of 10 patients were included(mean age 63.80±12.55 years).Uncorrected and corrected visual acuity(far,intermediate and near),subjective refraction,binocular defocus curve,contrast sensitivity(CSV-1000)and quality of vision and satisfaction questionnaires were measured.The follow-up was 12 months after surgery.Results:At 12 months after surgery,uncorrected distance visual acuity(UDVA)improved with surgery(P=0.001)with a value of 0.08±0.08 logMAR.Uncorrected near visual acuity(UNVA)was 0.22±0.12 logMAR and distance corrected near visual acuity(DCNVA)was 0.16±0.13 logMAR.Intermediate distance visual acuity(UIVA)was 0.22±0.10 logMAR.Contrast sensitivity outcomes were similar to normal population in photopic conditions and slightly reduced in mesopic conditions of lighting.Defocus curve showed that this multifocal IOL was able to provide a visual acuity(VA)equal to or better than 0.16 logMAR between defocus levels of+1.00 to-2.50 D.Good patient satisfaction was obtained in quality of vision and satisfaction questionnaires outcomes.Conclusions:The Precizon Presbyopic NVA IOL(OPHTEC BV)provides good visual outcomes.This multifocal IOL provides a high percentage of spectacle independence due to good VA at far,intermediate and near distances and satisfactory contrast sensitivity.High patient satisfaction was observed in quality of vision and satisfaction questionnaires with a low percentage of patients manifesting photic phenomena.
文献关键词:
中图分类号:
作者姓名:
Jorge L.Alió;Pilar Yébana;Mario Cantó;Ana B.Plaza;Alfredo Vega;Jorge L.Alió del Barrio;Francisco Lugo
作者机构:
Vissum Corporation,Avda de Denia s/n,Edificio Vissum,03016 Alicante,Spain;Division of Ophthalmology,Universidad Miguel Hernández,Alicante,Spain
文献出处:
引用格式:
[1]Jorge L.Alió;Pilar Yébana;Mario Cantó;Ana B.Plaza;Alfredo Vega;Jorge L.Alió del Barrio;Francisco Lugo-.Clinical outcomes with a new design in multifocal intraocular lens:a pilot study)[J].眼视光学杂志(英文版),2022(05):13-21
A类:
Precizon,Presbyopic,Uncorrected,mesopic,of+1,NVA,OPHTEC,spectacle
B类:
Clinical,outcomes,new,design,multifocal,intraocular,lens,pilot,study,Purpose,To,evaluate,clinical,visual,quality,near,vision,influence,photic,phenomena,patients,bilaterally,implanted,IOL,Methods,this,prospective,consecutive,case,series,eyes,were,included,mean,years,acuity,far,intermediate,subjective,refraction,binocular,defocus,curve,contrast,sensitivity,CSV,satisfaction,questionnaires,measured,follow,up,was,months,after,surgery,Results,At,uncorrected,UDVA,improved,value,logMAR,UNVA,DCNVA,Intermediate,UIVA,Contrast,similar,normal,population,photopic,conditions,slightly,reduced,lighting,Defocus,showed,that,able,equal,better,than,between,levels,Good,obtained,Conclusions,BV,provides,good,This,high,percentage,independence,due,distances,satisfactory,High,observed,manifesting
AB值:
0.45403
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。