Improved sensitivity on detection of Cu and Cr in liquids using glow discharge technology assisted with LIBS
文献摘要:
Laser-induced breakdown spectroscopy-assisted glow discharge(LIBS-GD)for analysis of elements in liquid was proposed,and it was applied to detect heavy metals in highly sensitive mixed solutions of Cu and Cr.During the experiments of GD and LIBS-GD,the experimental parameters have been optimized and the optimal voltage is 450 V,laser energy is 60 mJ,and the delay time is 4000 ns.Furthermore,the calibration curves of Cu and Cr under GD and LIBS-GD experiments have been established,and the limits of detection(LODs)of Cu and Cr were obtained with the method of GD and LIBS-GD,respectively.The LOD of Cu decreased from 3.37(GD)to 0.16 mg l-1(LIBS-GD),and Cr decreased from 3.15 to 0.34 mg 1-1.The results prove that the capability of elemental detection under LIBS-GD has improved compared with the GD method.Therefore,LIBS-GD is expected to be developed into a highly sensitive method for sewage detection.
文献关键词:
作者姓名:
Duixiong SUN;Yarui WANG;Maogen SU;Weiwei HAN;Chenzhong DONG
作者机构:
Key Laboratory of Atomic and Molecular Physics&Functional Material of Gansu Province,College of Physics and Electronic Engineering,Northwest Normal University,Lanzhou 730070,People's Republic of China;Joint Laboratory of Atomic and Molecular Physics,Northwest Normal University and Institute of Modern Physics of Chinese Academy of Sciences,Lanzhou 730070,People's Republic of China
引用格式:
[1]Duixiong SUN;Yarui WANG;Maogen SU;Weiwei HAN;Chenzhong DONG-.Improved sensitivity on detection of Cu and Cr in liquids using glow discharge technology assisted with LIBS)[J].等离子体科学和技术(英文版),2022(08):64-70
A类:
B类:
Improved,sensitivity,detection,liquids,using,glow,discharge,technology,assisted,LIBS,Laser,induced,breakdown,spectroscopy,GD,analysis,elements,was,proposed,applied,heavy,metals,highly,sensitive,mixed,solutions,During,experiments,experimental,parameters,have,been,optimized,optimal,voltage,laser,energy,mJ,delay,Furthermore,calibration,curves,under,established,limits,LODs,were,obtained,method,respectively,decreased,from,results,that,capability,elemental,has,improved,compared,Therefore,expected,developed,into,sewage
AB值:
0.462234
相似文献
Experimental and numerical investigation into the non-explosive excavation of tunnels
Quan Zhang;Zhigang Tao;Chun Yang;Shan Guo;Manchao He;Chongyuan Zhang;Huiya Niu;Chao Wang;Shen Wang-School of Mines,China University of Mining and Technology,Xuzhou,Jiangsu,221116,China;State Key Laboratory of Geomechanics and Deep Underground Engineering,China University of Mining and Technology,Beijing,100083,China;School of Resources and Safety Engineering,Central South University,Changsha,410083,China;Department of Mining and Materials Engineering,McGill University,Montreal,QC,H3A 0E8,Canada;Institute of Geomechanics,Chinese Academy of Geological Sciences,Beijing,100081,China;College of Environmental Science and Engineering,Ocean University of China,Qingdao,266100,China;School of Energy Science and Engineering,Henan Polytechnic University,Jiaozuo,454003,China