首站-论文投稿智能助手
典型文献
Megapixel X-ray ghost imaging with a binned detector in the object arm
文献摘要:
At present,reconstruction of megapixel and high-fidelity images with few measurements is a major challenge for X-ray ghost imaging[XGI].The available strategies require massive measurements and reconstruct low-fidelity images of less than 300×300 pixels.Inspired by the concept of synthetic aperture radar,synthetic aperture XGI[SAXGi]integrated with compressive sensing is proposed to solve this problem with a binned detector in the object arm.Experimental results demonstrated that SAXGI can accurately reconstruct the 1200×1200 pixels image of a binary sample of tangled strands of tungsten fiber from 660 measurements.Accordingly,SAXGI is a promising solution for the practical application of XGI.
文献关键词:
作者姓名:
Haipeng Zhang;Ke Li;Feixiang Wang;Hong Yu;Changzhe Zhao;Guohao Du;Zhongliang Li;Biao Deng;Honglan Xie;Shensheng Han;Tiqiao Xiao
作者机构:
Shanghai Institute of Applied Physics,Chinese Academy of Sciences,Shanghai 201800,China;Shanghai Synchrotron Radiation Facility/Zhangjiang Lab,Shanghai Advanced Research Institute,Chinese Academy of Sciences,Shanghai 201204,China;University of Chinese Academy of Sciences,Beijing 100049,China;Shanghai Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Shanghai 201800,China
引用格式:
[1]Haipeng Zhang;Ke Li;Feixiang Wang;Hong Yu;Changzhe Zhao;Guohao Du;Zhongliang Li;Biao Deng;Honglan Xie;Shensheng Han;Tiqiao Xiao-.Megapixel X-ray ghost imaging with a binned detector in the object arm)[J].中国光学快报(英文版),2022(03):145-152
A类:
Megapixel,binned,megapixel,XGI,SAXGi,SAXGI
B类:
ray,ghost,imaging,detector,object,arm,At,present,reconstruction,high,fidelity,images,few,measurements,major,challenge,available,strategies,require,massive,low,less,than,pixels,Inspired,by,concept,synthetic,aperture,radar,integrated,compressive,sensing,proposed,solve,this,problem,Experimental,results,demonstrated,that,can,accurately,binary,sample,tangled,strands,tungsten,fiber,from,Accordingly,promising,solution,practical,application
AB值:
0.515757
相似文献
Robust restoration of low-dose cerebral perfusion CT images using NCS-Unet
Kai Chen;Li-Bo Zhang;Jia-Shun Liu;Yuan Gao;Zhan Wu;Hai-Chen Zhu;Chang-Ping Du;Xiao-Li Mai;Chun-Feng Yang;Yang Chen-Southeast University,Nanjing 210096,China;School of Cyber Science and Engineering,Southeast University,Nanjing 210096,China;Key Laboratory of Computer Network and Information Integration(Southeast University),Ministry of Education,Nanjing 210096,China;Department of Radiology,General Hospital of the Northern Theater of the Chinese People's Liberation Army,Shenyang 110016,China;Laboratory of Image Science and Technology,The School of Computer Science and Engineering,Southeast University,Nanjing 210096,China;Department of Radiology,Nanjing Drum Tower Hospital,The Affiliated Hospital of Nanjing University Medical School,Nanjing 210008,China;Jiangsu Key Laboratory of Molecular and Functional Imaging,Department of Radiology,Zhongda Hospital,Southeast University,Nanjing 210009,China;Jiangsu Provincial Joint International Research Laboratory of Medical Information Processing,School of Computer Science and Engineering,Southeast University,Nanjing 210096,China
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。