Continuous cardiac output measured with a Swan- Ganz catheter reacts too slowly in animal experiments with sudden circulator y failure
文献摘要:
Background : In many animal experiments, it is vital to detect sudden changes in car-diac output (CO). This porcine study compared CO that was measured with a Swan- Ganz pulmonary catheter with the gold standard (which was a transit- time flow probe around the pulmonary artery) during interventions that caused hemodynamic instability. Methods : In one series, 7 pigs were exposed to sudden changes in CO. In another se-ries, 9 pigs experienced more prolonged changes in CO. All the pigs had a Swan- Ganz catheter placed into the pulmonary artery and a flow probe around the pulmonary artery. Adrenaline infusion and controlled hemorrhage were used to increase and de-crease CO, respectively. The measurements of CO before and after each interven-tion were compared for correlation, agreement, and the time delay that it took each method to detect at least a 30% change in CO. A Bland– Altman test was used to identify correlations and agreements between the methods. Results : In the first series, there was a delay of 5– 7 min for the Swan Ganz catheter to register a 30% change in cardiac output, compared with the flow probe. However, during prolonged changes in CO in the second series, there was a good correlation between the 2 methods. Mixed venous oxygen saturation reacted faster to changes than did CO; both were measured via the Swan- Ganz catheter. Conclusions : In many animal studies, the use of Swan- Ganz catheters is suitable; how-ever, in experiments with sudden hemodynamic instability, the flow probe is the most advantageous method for measuring CO.
文献关键词:
中图分类号:
作者姓名:
Sigríeur Olga Magnúsdóttir;Carsten Simonsen;Bodil Steen Rasmussen;Peter Enemark Lund;Benedict Kj?rgaard
作者机构:
Biomedical Research Laboratory,Aalborg University Hospital,Aalborg,Denmark;Department of Clinical Medicine,Aalborg University,Aalborg,Denmark;Department of Cardiothoracic Surgery,Aalborg University Hospital,Aalborg, Denmark;Department of Anesthesia and Intensive Care,Aalborg University Hospital, Aalborg,Denmark;Unit of Clinical Biostatistics,Aalborg University Hospital,Aalborg,Denmark
文献出处:
引用格式:
[1]Sigríeur Olga Magnúsdóttir;Carsten Simonsen;Bodil Steen Rasmussen;Peter Enemark Lund;Benedict Kj?rgaard-.Continuous cardiac output measured with a Swan- Ganz catheter reacts too slowly in animal experiments with sudden circulator y failure)[J].动物模型与实验医学(英文),2022(03):258-265
A类:
B类:
Continuous,cardiac,output,measured,Swan,Ganz,reacts,slowly,animal,experiments,sudden,circulator,failure,Background,In,many,vital,detect,changes,This,porcine,study,compared,that,was,pulmonary,gold,standard,which,transit,flow,probe,around,artery,during,interventions,caused,hemodynamic,instability,Methods,one,series,pigs,were,exposed,another,experienced,more,prolonged,All,had,placed,into,Adrenaline,infusion,controlled,hemorrhage,increase,respectively,measurements,before,after,each,delay,took,least,Bland,Altman,test,identify,correlations,agreements,between,methods,Results,first,there,register,However,second,good,Mixed,venous,oxygen,saturation,reacted,faster,than,did,both,via,Conclusions,studies,catheters,suitable,how,most,advantageous,measuring
AB值:
0.429893
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。