典型文献
Design and development of an ACCT for the Shanghai advanced proton therapy facility
文献摘要:
The Shanghai advanced proton therapy facility is a proton cancer treatment device designed and built by the Shanghai Institute of applied physics at the Chinese acad-emy of sciences.The accelerator part comprises a proton linear accelerator(linac)injector and a circular syn-chrotron.An alternating current current transformer(ACCT)is used for non-intercepting beam current mea-surement at the drift tube linac exit.According to the beam characteristics,the ACCT is required to complete real-time beam current and pulse width measurements at currents of 3-30 mA,frequencies of 1-10 Hz,and pulse widths of 40-400 μs.In this paper,we report the design and devel-opment of an ACCT.The designed ACCT was simulated using CST Microwave Studio,and calibrated using an oscilloscope and signal generator.Variations in the output signal of the ACCT were investigated as a function of ceramic gap size,number of coil turns,and resistance.According to the simulation and experimental results,the optimal number of coil turns was found to be 30.In addition,a low-pass filter was adopted to filter the noise introduced during long-distance signal transmission using a coaxial cable with the length of 20 m.The calibration results show that the corresponding rise time of the ACCT is 800 ns with the sensitivity of 8.2 V/A and a droop of less than 1%,meeting the design requirements.
文献关键词:
中图分类号:
作者姓名:
Hong Zhang;Jun-Zhou Li;Rui Hou;Sun An;Shi-Quan Xu;You-Chun Liu;Peng-Jiao Zhang;Jie Song;Yue-Lin Zhang
作者机构:
College of Engineering and Applied Sciences,Nanjing University,Nanjing 210093,China
文献出处:
引用格式:
[1]Hong Zhang;Jun-Zhou Li;Rui Hou;Sun An;Shi-Quan Xu;You-Chun Liu;Peng-Jiao Zhang;Jie Song;Yue-Lin Zhang-.Design and development of an ACCT for the Shanghai advanced proton therapy facility)[J].核技术(英文版),2022(10):41-52
A类:
acad
B类:
Design,development,ACCT,Shanghai,advanced,proton,therapy,facility,cancer,treatment,device,designed,built,by,Institute,applied,physics,Chinese,emy,sciences,accelerator,part,comprises,linear,linac,injector,circular,syn,chrotron,An,alternating,transformer,used,intercepting,beam,drift,tube,exit,According,characteristics,required,complete,real,pulse,measurements,currents,mA,frequencies,widths,this,paper,report,was,simulated,using,CST,Microwave,Studio,calibrated,oscilloscope,signal,generator,Variations,output,were,investigated,function,ceramic,gap,size,number,coil,turns,resistance,simulation,experimental,results,optimal,found,addition,low,pass,filter,adopted,noise,introduced,during,long,distance,transmission,coaxial,cable,length,calibration,show,that,corresponding,sensitivity,droop,less,than,meeting,requirements
AB值:
0.54251
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。