首站-论文投稿智能助手
典型文献
Distributed DC-Bus Signaling Control of Photovoltaic Systems in Islanded DC Microgrid
文献摘要:
The stability of an islanded DC microgrid(DCMG)is highly dependent on the presence and performance of the backup energy storage system(BESS),due to the lack of main grid support.This condition makes the DCMG vulnerable to the critical situation of absence of the BESS,which could be caused by a fault or being fully charged or flat.This paper presents an enhanced distributed DC-bus signaling control strategy for converters of photovoltaic systems(PVs)to make the islanded DCMG less dependent on the BESS.Unlike a conventional control approach that utilizes PVs to operate in maximum power point tracking(MPPT)mode and the BESS solely regulating DC-bus voltage,the proposed control method maintains DC-bus voltage via intelligently managing output powers of the PVs.The proposed control method continuously monitors DC-bus voltage and regulates the output powers of all the PVs via switching between MPPT mode and voltage regulating mode.Accordingly,if the DC-bus voltage level is less than a predefined maximum level,the PVs work in MPPT mode;otherwise,the PVs work in voltage regulating mode to maintain DC-bus voltage at an acceptable range.Such switching between MPPT and voltage regulating control operations results in protecting the DCMG from unavoidable shutdowns conventionally necessary during the absence of the BESS unit.Moreover,the proposed control method reduces oscillations on the DC-bus voltage during existence of the BESS.The performance and effectiveness of the proposed control strategy are validated through different case studies in MATLAB/Simulink.
文献关键词:
作者姓名:
Noushin Poursafar;M.J.Hossain;Seyedfoad Taghizadeh
作者机构:
Macquarie University,Sydney,New South Wales,Australia
引用格式:
[1]Noushin Poursafar;M.J.Hossain;Seyedfoad Taghizadeh-.Distributed DC-Bus Signaling Control of Photovoltaic Systems in Islanded DC Microgrid)[J].中国电机工程学会电力与能源系统学报(英文版),2022(06):1741-1750
A类:
Islanded,islanded,DCMG,shutdowns
B类:
Distributed,Bus,Signaling,Control,Photovoltaic,Systems,Microgrid,stability,microgrid,highly,dependent,presence,performance,backup,energy,storage,BESS,due,lack,support,This,condition,makes,vulnerable,critical,situation,absence,which,could,caused,by,fault,being,fully,charged,flat,paper,presents,enhanced,distributed,bus,signaling,control,strategy,converters,photovoltaic,systems,PVs,less,Unlike,approach,that,utilizes,operate,maximum,point,tracking,MPPT,mode,solely,regulating,voltage,proposed,method,maintains,via,intelligently,managing,output,powers,continuously,monitors,regulates,switching,between,Accordingly,level,than,predefined,work,otherwise,acceptable,range,Such,operations,results,protecting,from,unavoidable,conventionally,necessary,during,unit,Moreover,reduces,oscillations,existence,effectiveness,are,validated,through,different,case,studies,Simulink
AB值:
0.460452
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。