首站-论文投稿智能助手
典型文献
Pilot Protection Based on Amplitude Comparison for Renewable Power Teed Lines
文献摘要:
Fault behaviors of inverter-interfaced renewable energy generators(IIREGs)are quite diverse from those of synchronous generators(SGs).They show the variable system impedance,the limited current and low inertia,so the propor-tional brake differential protection installed on the transmission line has a high risk of failure for phase-phase failures.To cope with this adaptive problem,a new pilot protection is proposed considering the huge differences in both current amplitudes.Also,an improved criterion is presented for a scenario with a teed line.The existing protection principles focus excessively on the fault current characteristics of IIREGs,so they cannot operate correctly once IIREGs do not output their fault current.This happens when IIREGs produce no power or the circuit breakers exactly reclose on permanent failures.However,the proposed method has good performance for the above cases.The proposed method only requires current amplitude information,and in this case the strict synchronizing measurement is not necessary.Case studies are performed under different fault conditions,and they confirm the proposed method has good performance under different fault conditions.Furthermore,it is also verified using field-testing data.
文献关键词:
作者姓名:
Ke Jia;Zhe Yang;Yu Fang;Zhengxuan Zhu;Liming Zheng;Tianshu Bi;Ali Hooshyar
作者机构:
State Key Laboratory of Alternative Electrical Power System with Renewable Energy Sources,North China Electric Power University,Beijing 102206,China;Department of Electrical and Computer Engineering,University of Toronto,Toronto,ON M5S 3G4,Canada
引用格式:
[1]Ke Jia;Zhe Yang;Yu Fang;Zhengxuan Zhu;Liming Zheng;Tianshu Bi;Ali Hooshyar-.Pilot Protection Based on Amplitude Comparison for Renewable Power Teed Lines)[J].中国电机工程学会电力与能源系统学报(英文版),2022(06):1519-1529
A类:
Teed,IIREGs,teed,reclose
B类:
Pilot,Protection,Based,Amplitude,Comparison,Renewable,Power,Lines,Fault,behaviors,inverter,interfaced,renewable,energy,generators,are,quite,diverse,from,those,synchronous,SGs,They,show,variable,system,impedance,limited,current,low,inertia,propor,tional,brake,differential,protection,installed,transmission,line,high,risk,phase,failures,To,cope,this,adaptive,problem,pilot,proposed,considering,huge,differences,both,amplitudes,Also,improved,criterion,presented,scenario,existing,principles,focus,excessively,fault,characteristics,they,cannot,operate,correctly,once,do,output,their,This,happens,when,produce,power,circuit,breakers,exactly,permanent,However,method,good,performance,above,cases,only,requires,information,strict,synchronizing,measurement,necessary,Case,studies,performed,under,conditions,confirm,Furthermore,also,verified,using,field,testing,data
AB值:
0.619551
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。