典型文献
Evaluation Value of Intravoxel Incoherent Motion Diffusion-Weighted Imaging on Early Efficacy of Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation for Uterine Adenomyoma
文献摘要:
To investigate the evaluation value of intravoxel incoherent motion diffusion-weighted imaging(IVIM-DWI)on the early efficacy of magnetic resonance-guided high-intensity focused ultrasound(MRgFUS)ablation for uterine adenomyoma.The clinical and magnetic resonance imaging(MRI)data of 36 patients with uterine adenomyoma before and after MRgFUS treatment in our hospital from January 2018 to December 2018 were retrospectively analyzed.All the 36 patients underwent MRI examination one day before operation and imme-diately after operation using GE Discovery MR750 3.0T MRI,including conventional sequences(T1WI,T2WI,and T2 fat suppression sequences)plain scan,IVIM-DWI sequences with 9 b values,and contrast enhanced-MRI sequences.The IVIM-DWI quantitative parameters(true diffusion coefficient D,perfusion related diffusion coef-ficient D*,and perfusion fraction f)of double-exponential model were obtained by using GE ADW 4.7 functool,a postprocessor.SPSS 24.0 software was used to analyze the difference in parameter between the ablation and non-ablation areas of uterine adenomyoma.DWI signal in the ablation area of uterine adenomyoma was increased,and manifested as heterogeneous diffuse high signal,with low central signal and high edge signal.Values of D,D*and f in the ablation area of uterine adenomyoma were significantly lower than those in the non-ablation area,and there was statistical difference between the two(P<0.05).The areas under receiver operating characteristic(ROC)curve of D,D*and f values in the ablation area of uterine adenomyoma were 0.854,0.898 and 0.924,respectively;the optimal thresholds for the diagnosis of ablation area of uterine adenomyoma were 0.81×10-3 mm2/s,4.99×10-3 mm2/s and 0.24,respectively;the diagnostic sensitivity was 80.6%,72.2%and 94.4%,respec-tively;and the specificity was 91.7%,97.2%and 94.4%,respectively.IVIM-DWI has a certain clinical value in the evaluation on early efficacy of MRgFUS ablation of uterine adenomyosis.
文献关键词:
中图分类号:
作者姓名:
TANG Na;GU Jianjun;YIN Xiaorui;YU Rongjiang;XU Yuantao;LI Xiang;WANG Han
作者机构:
Department of Radiology,Shanghai General Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200080,China
文献出处:
引用格式:
[1]TANG Na;GU Jianjun;YIN Xiaorui;YU Rongjiang;XU Yuantao;LI Xiang;WANG Han-.Evaluation Value of Intravoxel Incoherent Motion Diffusion-Weighted Imaging on Early Efficacy of Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation for Uterine Adenomyoma)[J].上海交通大学学报(英文版),2022(02):226-230
A类:
Incoherent,Adenomyoma,adenomyoma,MR750,functool,postprocessor
B类:
Evaluation,Intravoxel,Motion,Diffusion,Weighted,Imaging,Early,Efficacy,Magnetic,Resonance,Guided,High,Intensity,Focused,Ultrasound,Ablation,Uterine,To,investigate,evaluation,intravoxel,incoherent,motion,diffusion,weighted,imaging,IVIM,DWI,early,efficacy,magnetic,resonance,guided,high,intensity,focused,ultrasound,MRgFUS,ablation,uterine,clinical,data,patients,before,after,treatment,our,hospital,from,January,December,were,retrospectively,analyzed,All,underwent,examination,day,operation,imme,diately,using,GE,Discovery,0T,including,conventional,sequences,T1WI,T2WI,fat,suppression,plain,scan,values,contrast,enhanced,quantitative,parameters,true,coefficient,perfusion,related,fraction,double,exponential,model,obtained,by,ADW,software,was,difference,between,areas,signal,increased,manifested,heterogeneous,diffuse,central,edge,Values,significantly,lower,than,those,there,statistical,two,receiver,operating,characteristic,curve,respectively,optimal,thresholds,diagnosis,mm2,diagnostic,sensitivity,specificity,has,certain,adenomyosis
AB值:
0.480244
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。