典型文献
Improvement of Physical Fitness Test Assessment Criteria Based on fNIRS Technology:Taking Pull-Up as an Example
文献摘要:
Pull-up,as an important physical fitness test event of the"National Student Physical Health Standard",is known as a difficult physical fitness test event.To improve the assessment criteria of pull-ups,this paper uses the functional near-infrared spectroscopy(fNIRS)to monitor the changes and activation of oxyhemoglobin(HbO)signals in the brain motor cortex of people with different body mass indexes(BMIs)during the pull-up assessment.Then the relationship between BMIs and evaluation criteria is discussed.After collecting and analyzing experimental data of 18 recruited college students,it is found that the number of pull-ups performed by people with different BMIs is different when they reach the peak state of brain activation.The results of the study indicate that different assessment criteria should be adopted for different BMI groups.It is suggested that the BMI should be introduced as one of the test indexes in the examination of pull-ups event in"National Student Physical Health Standard".
文献关键词:
中图分类号:
作者姓名:
GONG Bin;YU Xianghua;FANG Yu;WANG Zheng;YANG Hao;CHEN Guodong;Lü Na
作者机构:
School of Mechanical and Automotive Engineering,Shanghai University of Engineering Science,Shanghai 201620,China;Shanghai Jiao Tong University Affiliated Sixth People's Hospital,Shanghai 200233,China;School of Mechanical and Electrical Engineering,Soochow University,Suzhou 215006,Jiangsu,China;School of Mechanical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China
文献出处:
引用格式:
[1]GONG Bin;YU Xianghua;FANG Yu;WANG Zheng;YANG Hao;CHEN Guodong;Lü Na-.Improvement of Physical Fitness Test Assessment Criteria Based on fNIRS Technology:Taking Pull-Up as an Example)[J].上海交通大学学报(英文版),2022(02):219-225
A类:
oxyhemoglobin,BMIs
B类:
Improvement,Physical,Fitness,Test,Assessment,Criteria,Based,fNIRS,Technology,Taking,Pull,Up,Example,important,physical,fitness,test,event,National,Student,Health,Standard,known,difficult,To,improve,assessment,criteria,pull,this,paper,uses,functional,near,infrared,spectroscopy,monitor,changes,activation,HbO,signals,brain,motor,cortex,people,different,body,mass,indexes,during,Then,relationship,between,evaluation,discussed,After,collecting,analyzing,experimental,data,recruited,college,students,found,that,number,performed,by,when,they,reach,peak,state,results,study,indicate,should,adopted,groups,It,suggested,introduced,one,examination
AB值:
0.532551
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。