典型文献
A Microfluidic System with Active Mixing for Improved Real-Time Isothermal Amplification
文献摘要:
To improve the performance of real-time recombinase polymerase amplification (RPA), a microfluidic system with active mixing is developed to optimize the reaction dynamics. Instead of adopting a single typical reaction chamber, a specific reactor including a relatively large chamber in center with two adjacent zig-zag channels at two sides is integrated into the microfluidic chip. Active mixing is achieved by driving the viscous reagent between the chamber and the channel back and forth periodically with an outside compact peristaltic pump. To avoid reagent evapora-tion, one end of the reactor is sealed with paraffin oil. A hand-held companion device is developed to facilitate real-time RPA amplification within 20 min. The whole area of the reactor is heated with a resistance heater to provide uniform reaction temperature. To achieve real-time monitoring, a compact fluorescence detection module is integrated into the hand-held device. A smartphone with custom application software is adopted to control the hand-held device and display the real-time fluorescence curves. The performances of two cases with and without active on-chip mixing are compared between each other by detecting African swine fever viruses. It has been demonstrated that, with active on-chip mixing, the amplification efficiency and detection sensitivity can be signifi-cantly improved.
文献关键词:
中图分类号:
作者姓名:
Dianlong Yang;Xiaodan Jiang;Yijie Zhou;Xiaobin Dong;Luyao Liu;Lulu Zhang;Xianbo Qiu
作者机构:
College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029, China
文献出处:
引用格式:
[1]Dianlong Yang;Xiaodan Jiang;Yijie Zhou;Xiaobin Dong;Luyao Liu;Lulu Zhang;Xianbo Qiu-.A Microfluidic System with Active Mixing for Improved Real-Time Isothermal Amplification)[J].北京理工大学学报(英文版),2022(03):275-284
A类:
zig,zag,evapora
B类:
Microfluidic,System,Active,Mixing,Improved,Real,Time,Isothermal,Amplification,To,real,recombinase,polymerase,amplification,RPA,microfluidic,system,active,mixing,developed,optimize,reaction,dynamics,Instead,adopting,single,typical,chamber,specific,reactor,including,relatively,large,center,two,adjacent,channels,sides,integrated,into,chip,achieved,by,driving,viscous,reagent,between,back,forth,periodically,outside,compact,peristaltic,pump,avoid,end,sealed,paraffin,oil,hand,held,companion,device,facilitate,within,whole,area,heated,resistance,heater,provide,uniform,temperature,monitoring,fluorescence,detection,module,smartphone,custom,application,software,adopted,control,display,curves,performances,cases,without,compared,each,detecting,African,swine,fever,viruses,It,has,been,demonstrated,that,efficiency,sensitivity,signifi,cantly,improved
AB值:
0.568322
相似文献
机标中图分类号,由域田数据科技根据网络公开资料自动分析生成,仅供学习研究参考。